Shop by Product Line
R-flex
WarmWire
Underfloor Heating Mats
ThermalPro
Tekmar Controls
Miscellaneous
Mixing Controls
Mixing Valves
Room Temperature Units
Sensors
Setpoint and Pump Controls
Snow Melting Controls
tekmarNet Controls
Thermostats
Manifolds
Heating System Controls
Tubing Fittings
Water Heaters & Boilers
TapeMats
Watts Onix Tubing
Watts Radiant RadiantPERT Coil
Coil Watts Radiant BarrierPEX+
SlabHeat
Nibco Barrier PEX
Nibco Dura Pex
  Tekmar Universal Reset Module - Two tN4, Mixing, Boiler, DHW & SP
Tekmar Universal Reset Module - Two tN4, Mixing, Boiler, DHW & SP
Click to enlarge

Tekmar Universal Reset Module - Two tN4, Mixing, Boiler, DHW & SP

The Universal Reset Module 422 is designed to operate all of the mechanical equipment in a hydronic heating system, except for zones, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler to multiple fan coils, mixed radiant floor zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, and can expand up to 24 zones in total for each heating water temperature.

Features

  • Automatic Boiler Differential
  • Boiler Protection
  • DHW Post Purge
  • DHW Priority (optional)
  • DHW control
  • Exercising
  • Expandable up to 48 zones
  • Indoor Temperature Feedback
  • One touch overrides (with optional User Switch)
  • Outdoor Temperature Reset
  • Powered pump outputs
  • Single on /off boiler control
  • System setback (with optional timer)
  • Variable speed, or floating action mixing control
  • Warm Weather Shut Down
  • Zone Synchronization

Specifications

Control Microprocessor PID control; This is not a safety (limit) control
Packaged weight 1.87 lb. (848 g)
Dimensions 3-5/8" H x 5-3/8" W x 9/16" D (92 x 137 x 14 mm)
Approvals CSA C US, CSA/UL 61010-1, meets Class B: ICES & FCC Part 15
Ambient conditions Indoor use only, 32 to 122°F (0 to 50°C), Max. RH 92% for temperatures up to 40°C, 50% RH at > 40°C, Altitude <6560 feet (2000 m), Installation Category II, Pollution Degree 2
Power Supply Provided by interconnected tekmarNet Zone Manager
Pump relays 115 V (ac) 5 A, 1/6 hp
Boiler Relay 115 V (ac) 5 A
Variable pump 115 V (ac) 2.5 A, fuse T2.5 A 250 V
Combined Load 10 A Max. (for DHW, Primary, Mixing & Var. Speed Pump)
Floating Action Output 24 V (ac) 8 VA Maximum
Modulation Output 0-10 V (dc) Minimum 2500
Demands 20-260 V (ac) / 0.1 VA @ 24 V
Sensors NTC thermistor, 10k @ 77°F (25°C ± 0.2°C) ß=3892
-Included utdoor Sensor 070 and 2 Universal Sensors 082
Warranty Limited 3 Year Warranty

Current Literature

Product Submittal

Jan 2011 - Present

422_Cpdf

Installation & Operation Manual

Aug 2007 - Present

422_Dpdf

Job Record

Aug 2009 - Present

422_Jpdf

Wiring Brochure

Mar 2009 - Present

422_Wpdf

Installing tN4 Reset Modules 420, 422 and 423 with Modulating Boilers

Mar 2011 - Present

SB0067pdf

RF Noise Interference

May 2009 - Present

SB0054pdf



Part Number: 422

Quantity
Price
1$735.97
2 +$682.93


 
 
Tell a Friend